ASTM on Data Normalisation: Difference between revisions
imported>WikiAdmin No edit summary |
imported>WikiAdmin No edit summary |
||
| Line 49: | Line 49: | ||
</math> | </math> | ||
Permeate back pressure</p> | Permeate back pressure</p> | ||
<p> | |||
<math> | |||
\pi = 0.006 \times | |||
</math> | |||
Average feed / brine conductivity</p> | |||
<p> | |||
<math> | |||
\text {Average feed / brine conductivity} = \text {Conductivity of feed} \times \left [ \frac{\ln \left ( \frac{1}{1-Y} \right )}{Y} \right ] | |||
</math> | |||
</p> | |||
Membrane rejection: normalised salt rejection, normalised permeate | Membrane rejection: normalised salt rejection, normalised permeate | ||
Feed/brine channel blockage/fouling: normalised differential pressure. | Feed/brine channel blockage/fouling: normalised differential pressure. | ||
Revision as of 02:34, 16 September 2014
ASTM D4516 - Standard Practice for Standardizing Reverse Osmosis Performance Data
Membrane performance (flux and salt passage) is affected by: water temperature, feed conductivity, and flux rate. If the operating arameters remain constant the system will perform fairly steadily over a long period of time. However, these operating conditions will eventually change. Normalisation is a technique that allows the user to standardise the data to a constant set of conditions (or to a reference), and may be used with SCADA for online diagnostics.
Flow or flux performance: specific flux, normalised flow.
Where:
NDP = Net Driving Pressure
RO feed pressure
Osmotic Pressure
Feed/Brine Differential Pressure
Number of membrane stages
Permeate back pressure
Average feed / brine conductivity
Membrane rejection: normalised salt rejection, normalised permeate Feed/brine channel blockage/fouling: normalised differential pressure.
Calculators/spreadsheets
Dow http://www.dowwaterandprocess.com/en/resources/normalization_of_membrane_systems
Hydronautics http://membranes.com/index.php?pagename=rodata