Perth Seawater Desalination Plant - Pretreatment: Difference between revisions

From Desal Wiki
imported>WikiAdmin
No edit summary
imported>WikiAdmin
No edit summary
 
(17 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Scheme Infobox Pretreatment
{{Scheme Infobox Pretreatment
   | image_name = x.png
   | image_name =
   | caption =
   | caption =
   | Hypochlorite = y
   | Hypochlorite = y
Line 10: Line 10:
   | Polymer =
   | Polymer =
   | Aluminium =
   | Aluminium =
   | Ferric Ferrous Iron = y
   | FerricFerrousIron = y
   | Carbon =
   | Carbon =
   | Sand Filtration = y
   | Sand Filtration = y
Line 18: Line 18:
   | Antiscalant Type =
   | Antiscalant Type =
   | Antiscalant Dose Rate =
   | Antiscalant Dose Rate =
   | Cartridge Filter Pore Size = 5 micron
   | Cartridge Filter Pore Size = [[Has Cartridge Filter Pore Size::5 µm]]
   | Cartridge Filter Exchange Frequency =
   | Cartridge Filter Exchange Frequency =
   | Acidification Type = Sulphuric Acid
   | Acidification Type = [[Sulphuric Acid]]
   | Acidification Desired pH =
   | Acidification Desired pH =
}}
}}
<!-- End Infobox template table -->
<!-- End Infobox template table -->
===General Description===
Feedwater is first dosed with ferric chloride following filtration in a system consisting of [[Has Horizontal pressure filters::24]] horizontal pressure filters, each having a surface area of 52 m2 and a 1.15 m deep filter bed of dual media. To protect the reverse osmosis membranes against physical fouling by suspended solids, filtered seawater is then passed through an array of 5-micron cartridge filters. Filter backwash water is treated using a high rate Densadeg gravity thickener and the sludge is dewatered for land disposal.
[[Category:Hypochlorite]]
[[Category:SMBS]]
[[Category:Ferric & Ferrous Iron]]
[[Category:Sand Filtration]]
[[Category:Cartridge Filters]]
[[Category:Acidification]]

Latest revision as of 00:07, 30 September 2014

Pretreatment Configuration
Cartridge Filters
Pore Size: 5 µm
Acidification
Type: Sulphuric Acid

General Description

Feedwater is first dosed with ferric chloride following filtration in a system consisting of 24 horizontal pressure filters, each having a surface area of 52 m2 and a 1.15 m deep filter bed of dual media. To protect the reverse osmosis membranes against physical fouling by suspended solids, filtered seawater is then passed through an array of 5-micron cartridge filters. Filter backwash water is treated using a high rate Densadeg gravity thickener and the sludge is dewatered for land disposal.