Perth Seawater Desalination Plant - Pretreatment: Difference between revisions
From Desal Wiki
imported>WikiAdmin |
imported>WikiAdmin No edit summary |
||
| (3 intermediate revisions by the same user not shown) | |||
| Line 18: | Line 18: | ||
| Antiscalant Type = | | Antiscalant Type = | ||
| Antiscalant Dose Rate = | | Antiscalant Dose Rate = | ||
| Cartridge Filter Pore Size = 5 | | Cartridge Filter Pore Size = [[Has Cartridge Filter Pore Size::5 µm]] | ||
| Cartridge Filter Exchange Frequency = | | Cartridge Filter Exchange Frequency = | ||
| Acidification Type = Sulphuric Acid | | Acidification Type = [[Sulphuric Acid]] | ||
| Acidification Desired pH = | | Acidification Desired pH = | ||
}} | }} | ||
Latest revision as of 00:07, 30 September 2014
| Pretreatment Configuration | |
|---|---|
*SMBS
| |
| Cartridge Filters | |
| Pore Size: | 5 µm |
| Acidification | |
| Type: | Sulphuric Acid |
General Description
Feedwater is first dosed with ferric chloride following filtration in a system consisting of 24 horizontal pressure filters, each having a surface area of 52 m2 and a 1.15 m deep filter bed of dual media. To protect the reverse osmosis membranes against physical fouling by suspended solids, filtered seawater is then passed through an array of 5-micron cartridge filters. Filter backwash water is treated using a high rate Densadeg gravity thickener and the sludge is dewatered for land disposal.