Perth Seawater Desalination Plant - RO: Difference between revisions
From Desal Wiki
imported>WikiAdmin No edit summary |
imported>WikiAdmin No edit summary |
||
| Line 21: | Line 21: | ||
===General Description=== | ===General Description=== | ||
The RO is a two-pass system with each of six first pass trains containing two membrane racks with each rack ultilizing 162 pressure vessels. The average Total Dissolved Solids (TDS) from the first pass is less than 300 mg/L. The six second pass trains each contain a single membrane rack with 102 pressure vessels, and have dedicated variable speed high pressure pums. The average TDS from the second pass is less than [[Has TDS below::30 mg/L]]. | The RO is a two-pass system with each of six first pass trains containing two membrane racks with each rack ultilizing 162 pressure vessels. The average Total Dissolved Solids (TDS) from the first pass is less than 300 mg/L. The six second pass trains each contain a single membrane rack with 102 pressure vessels, and have dedicated variable speed high pressure pums. The average TDS from the second pass is less than [[Has TDS below::30 mg/L]]. | ||
Latest revision as of 00:56, 26 November 2014
| RO Configuration | |
|---|---|
| Manufacturer: | Dow Filmtec |
| Number of Trains and Vessels | |
| Vessels in Stage 1: | 324 |
| Vessels in Stage 2: | 102 |
| Trains in Stage 1: | 6 |
| Trains in Stage 2: | 6 |
General Description
The RO is a two-pass system with each of six first pass trains containing two membrane racks with each rack ultilizing 162 pressure vessels. The average Total Dissolved Solids (TDS) from the first pass is less than 300 mg/L. The six second pass trains each contain a single membrane rack with 102 pressure vessels, and have dedicated variable speed high pressure pums. The average TDS from the second pass is less than 30 mg/L.