   | Manufacturer = Dow Filmtec
   | Manufacturer = Dow Filmtec
   | Model =
   | Model =
   | Vessels in Stage 1 =
   | Vessels in Stage 1 = 324
   | Vessels in Stage 2 =
   | Vessels in Stage 2 = 102
   | Trains in Stage 1 =
   | Trains in Stage 1 = 6
   | Trains in Stage 2 =
   | Trains in Stage 2 = 6
   | Elements per Vessel =
   | Elements per Vessel =
   | Membrane Element Size Diameter =
   | Membrane Element Size Diameter =
   | Membrane Element Size Length =
   | Membrane Element Size Length =
   | Feed Pressure =
   | Feed Pressure =
   | Feed Flow = y
   | Feed Flow =  
   | Permeate Pressure =
   | Permeate Pressure =
   | Permeate Flow = y
   | Permeate Flow =  
   | Concentrate Pressure =
   | Concentrate Pressure =
   | Current Salt Rejection =
   | Current Salt Rejection =
Line 21: Line 21:
===General Description===
===General Description===
The RO is a two-pass system with each of six first pass trains containing two membrane racks with each rack ultilizing 162 pressure vessels. The average Total Dissolved Solids (TDS) from the first pass is less than 300 mg/L. The six second pass trains each contain a single membrane rack with 102 pressure vessels, and have dedicated variable speed high pressure pums. The average TDS from the second pass is less than [[Has TDS below::30 mg/L]].
The RO is a two-pass system with each of six first pass trains containing two membrane racks with each rack ultilizing 162 pressure vessels. The average Total Dissolved Solids (TDS) from the first pass is less than 300 mg/L. The six second pass trains each contain a single membrane rack with 102 pressure vessels, and have dedicated variable speed high pressure pums. The average TDS from the second pass is less than [[Has TDS below::30 mg/L]].
[[Category:]]
[[Category:]]
[[Category:]]
[[Category:]]
[[Category:]]
[[Category:]]

Latest revision as of 00:56, 26 November 2014

RO Configuration
Manufacturer: Dow Filmtec
Number of Trains and Vessels
Vessels in Stage 1: 324
Vessels in Stage 2: 102
Trains in Stage 1: 6
Trains in Stage 2: 6

General Description

The RO is a two-pass system with each of six first pass trains containing two membrane racks with each rack ultilizing 162 pressure vessels. The average Total Dissolved Solids (TDS) from the first pass is less than 300 mg/L. The six second pass trains each contain a single membrane rack with 102 pressure vessels, and have dedicated variable speed high pressure pums. The average TDS from the second pass is less than 30 mg/L.