ASTM on Data Normalisation: Difference between revisions
imported>WikiAdmin |
imported>WikiAdmin |
||
| Line 80: | Line 80: | ||
</p> | </p> | ||
==Membrane rejection | ==Membrane rejection | ||
===Normalised Salt Rejection=== | |||
===Normalised Permeate Conductivity=== | |||
==Feed/brine channel blockage/fouling - normalised differential pressure== | ==Feed/brine channel blockage/fouling - normalised differential pressure== | ||
Revision as of 19:39, 16 September 2014
ASTM D4516 - Standard Practice for Standardizing Reverse Osmosis Performance Data
Membrane performance (flux and salt passage) is affected by: water temperature, feed conductivity, and flux rate. If the operating arameters remain constant the system will perform fairly steadily over a long period of time. However, these operating conditions will eventually change. Normalisation is a technique that allows the user to standardise the data to a constant set of conditions (or to a reference), and may be used with SCADA for online diagnostics.
Flow or flux performance
Specific flux
Where:
NDP = Net Driving Pressure
RO feed pressure
Osmotic Pressure
Feed/Brine Differential Pressure
Number of membrane stages
Permeate back pressure
Average feed / brine conductivity
Normalised Flow
==Membrane rejection
Normalised Salt Rejection
Normalised Permeate Conductivity
Feed/brine channel blockage/fouling - normalised differential pressure
Calculators/spreadsheets
Dow http://www.dowwaterandprocess.com/en/resources/normalization_of_membrane_systems
Hydronautics http://membranes.com/index.php?pagename=rodata