\text {Normalised} \hspace {2mm} \Delta P=\Delta P\left [ \frac{\left ( \text {Standard feed/brine flow} \right )^{1.5}}{\left (\text {Actual feed/brine flow} \right )^{1.5}} \right ]\left [\left ( T-25 \right )\left ( 0.017 \right ) +1 \right ] | \text {Normalised} \hspace {2mm} \Delta P=\Delta P\left [ \frac{\left ( \text {Standard feed/brine flow} \right )^{1.5}}{\left (\text {Actual feed/brine flow} \right )^{1.5}} \right ]\left [\left ( T-25 \right )\left ( 0.017 \right ) +1 \right ] | ||
</math> | </math> | ||
<p> | |||
<math> | |||
\text {Feed/brine flow}=\frac{\left ( \text {Feed flow} + \text {Concentrate flow} \right )}{2} | |||
</math> | |||
</p> | |||
==Calculators/spreadsheets== | ==Calculators/spreadsheets== | ||
Revision as of 23:45, 16 September 2014
ASTM D4516 - Standard Practice for Standardizing Reverse Osmosis Performance Data
Membrane performance (flux and salt passage) is affected by: water temperature, feed conductivity, and flux rate. If the operating arameters remain constant the system will perform fairly steadily over a long period of time. However, these operating conditions will eventually change. Normalisation is a technique that allows the user to standardise the data to a constant set of conditions (or to a reference), and may be used with SCADA for online diagnostics.
Flow or flux performance
Specific flux
Where:
NDP = Net Driving Pressure
RO feed pressure
Osmotic Pressure
Feed/Brine Differential Pressure
Number of membrane stages
Permeate back pressure
Average feed / brine conductivity
Normalised Flow
==Membrane rejection
Normalised Salt Rejection
Normalised Permeate Conductivity
Feed/brine channel blockage/fouling
Normalised differential pressure
Failed to parse (unknown function "\hspace"): {\displaystyle \text {Normalised} \hspace {2mm} \Delta P=\Delta P\left [ \frac{\left ( \text {Standard feed/brine flow} \right )^{1.5}}{\left (\text {Actual feed/brine flow} \right )^{1.5}} \right ]\left [\left ( T-25 \right )\left ( 0.017 \right ) +1 \right ] }
Calculators/spreadsheets
Dow http://www.dowwaterandprocess.com/en/resources/normalization_of_membrane_systems