ASTM on Data Normalisation

From Desal Wiki
Revision as of 02:42, 16 September 2014 by imported>WikiAdmin

ASTM D4516 - Standard Practice for Standardizing Reverse Osmosis Performance Data

Membrane performance (flux and salt passage) is affected by: water temperature, feed conductivity, and flux rate. If the operating arameters remain constant the system will perform fairly steadily over a long period of time. However, these operating conditions will eventually change. Normalisation is a technique that allows the user to standardise the data to a constant set of conditions (or to a reference), and may be used with SCADA for online diagnostics.

Flow or flux performance - specific flux, normalised flow

Where:

NDP = Net Driving Pressure

RO feed pressure

Osmotic Pressure

Feed/Brine Differential Pressure

Number of membrane stages

Permeate back pressure

Average feed / brine conductivity


Membrane rejection: normalised salt rejection, normalised permeate Feed/brine channel blockage/fouling: normalised differential pressure.

Calculators/spreadsheets

Dow http://www.dowwaterandprocess.com/en/resources/normalization_of_membrane_systems

Hydronautics http://membranes.com/index.php?pagename=rodata