The RO is a two-pass system with each of six first pass trains containing two membrane racks with each rack ultilizing 162 pressure vessels. The average Total Dissolved Solids (TDS) from the first pass is less than 300 mg/L. The six second pass trains each contain a single membrane rack with 102 pressure vessels, and have dedicated variable speed high pressure pums. The average TDS from the second pass is less than [[Has TDS below::30 mg/L]]. | The RO is a two-pass system with each of six first pass trains containing two membrane racks with each rack ultilizing 162 pressure vessels. The average Total Dissolved Solids (TDS) from the first pass is less than 300 mg/L. The six second pass trains each contain a single membrane rack with 102 pressure vessels, and have dedicated variable speed high pressure pums. The average TDS from the second pass is less than [[Has TDS below::30 mg/L]]. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Latest revision as of 07:56, 25 November 2014
RO Configuration | |
---|---|
Manufacturer: | Dow Filmtec |
Number of Trains and Vessels | |
Vessels in Stage 1: | 324 |
Vessels in Stage 2: | 102 |
Trains in Stage 1: | 6 |
Trains in Stage 2: | 6 |
General Description
The RO is a two-pass system with each of six first pass trains containing two membrane racks with each rack ultilizing 162 pressure vessels. The average Total Dissolved Solids (TDS) from the first pass is less than 300 mg/L. The six second pass trains each contain a single membrane rack with 102 pressure vessels, and have dedicated variable speed high pressure pums. The average TDS from the second pass is less than 30 mg/L.