Standardised RO Testing

From Desal Wiki
Revision as of 19:07, 20 August 2015 by WikiAdmin (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

The performances of high pressure membranes can be assessed with standard testing methods, recommended by the suppliers and available on their websites or product descriptions. Those methods generally involve a feed solution of 32,000 ppm NaCl and pressure of 55 bar for SWRO, and 2,000 ppm at 15.5 bar for BWRO. SWRO membranes have performances ranging between 99.6 - 99.9% NaCl rejection and a permeability of 0.45 – 0.94 L.m⁻².h⁻¹.bar⁻¹. While BWRO membranes have a performance that ranges from 98.5 – 99.8% NaCl rejection and a permeability of 1.3 – 7.4 L.m⁻².h⁻¹.bar⁻¹. Overall, there is a trade-off between salt rejection and permeability, with an increase in productivity resulting in a decrease in product quality. Additionally, RO membranes can be modified for a variety of requirements, including high productivity, high rejections, low energy, low fouling and high boron rejection. For comparison, NF membranes by the same manufactures have a NaCl rejection between 55 – 90% with a permeability of between 6.3 and 8.6 L.m⁻².h⁻¹.bar⁻¹.